Physical Properties
Property
Value
Unit
Source
Δc H°liquid
-2030.00 ± 3.00
kJ/mol
NIST
Δf G°
-27.90
kJ/mol
Joback Calculated Property
Δf H°gas
-11.70 ± 4.40
kJ/mol
NIST
Δf H°liquid
-79.20 ± 3.10
kJ/mol
NIST
Δfus H°
22.41
kJ/mol
Joback Calculated Property
Δvap H°
67.00 ± 1.00
kJ/mol
NIST
log 10 WS
-5.18
Aq. Sol...
log Poct/wat
4.552
Crippen Calculated Property
McVol
135.290
ml/mol
McGowan Calculated Property
Pc
3530.46
kPa
Joback Calculated Property
Inp
[228.10; 1328.00]
Inp
1314.30
NIST
Inp
1326.80
NIST
Inp
1328.00
NIST
Inp
1318.00
NIST
Inp
1318.00
NIST
Inp
Outlier 228.10
NIST
Tboil
572.14
K
Joback Calculated Property
Tc
830.91
K
Joback Calculated Property
Tfus
412.03
K
Joback Calculated Property
Vc
0.520
m3 /kmol
Joback Calculated Property
Temperature Dependent Properties
Property
Value
Unit
Temperature (K)
Source
Cp,gas
[201.40; 222.01]
J/mol×K
[572.14; 830.91]
Cp,gas
201.40
J/mol×K
572.14
Joback Calculated Property
Cp,gas
205.15
J/mol×K
615.27
Joback Calculated Property
Cp,gas
208.54
J/mol×K
658.40
Joback Calculated Property
Cp,gas
211.76
J/mol×K
701.52
Joback Calculated Property
Cp,gas
214.97
J/mol×K
744.65
Joback Calculated Property
Cp,gas
218.33
J/mol×K
787.78
Joback Calculated Property
Cp,gas
222.01
J/mol×K
830.91
Joback Calculated Property
Δsub H
73.60
kJ/mol
283.00
NIST
Δvap H
53.70
kJ/mol
423.50
NIST
Pressure Dependent Properties
Property
Value
Unit
Pressure (kPa)
Source
Tboilr
512.20
K
100.00
NIST
Correlations
Property
Value
Unit
Temperature (K)
Source
Pvap
[2.31e-03; 2930.13]
kPa
[284.49; 746.00]
KDB Vap...
Equation ln(Pvp) = A + B/T + C*ln(T) + D*T^2 Coefficient A 1.04916e+02 Coefficient B -1.11253e+04 Coefficient C -1.27868e+01 Coefficient D 4.60213e-06 Temperature range, min. 284.49
Temperature range, max. 746.00
Pvap
2.31e-03
kPa
284.49
Calculated Property
Pvap
0.13
kPa
335.77
Calculated Property
Pvap
1.96
kPa
387.05
Calculated Property
Pvap
13.98
kPa
438.33
Calculated Property
Pvap
60.34
kPa
489.61
Calculated Property
Pvap
185.64
kPa
540.88
Calculated Property
Pvap
452.22
kPa
592.16
Calculated Property
Pvap
935.51
kPa
643.44
Calculated Property
Pvap
1724.42
kPa
694.72
Calculated Property
Pvap
2930.13
kPa
746.00
Calculated Property
Similar Compounds
Find more compounds similar to Hexachlorocyclopentadiene .
Sources
Note: Cheméo is only indexing the data, follow the source links to retrieve the latest data. The source is also providing more information like the publication year, authors and more.
Take the time to validate and double check the source of the data.
Outlier This icon means
that the value is more than 2 standard deviations away from the
property mean.