Property | Value | Unit | Source |
---|---|---|---|
ΔcH°solid | -3752.88 ± 0.64 | kJ/mol | NIST |
ΔfG° | -251.48 | kJ/mol | Joback Calculated Property |
ΔfH°gas | -433.80 ± 1.20 | kJ/mol | NIST |
ΔfH°solid | -538.50 ± 1.20 | kJ/mol | NIST |
ΔfusH° | 23.90 | kJ/mol | Benzoic... |
ΔsubH° | [90.90; 110.70] | kJ/mol | |
ΔsubH° | 110.70 ± 0.80 | kJ/mol | NIST |
ΔsubH° | 104.70 | kJ/mol | NIST |
ΔsubH° | 104.70 ± 0.30 | kJ/mol | NIST |
ΔsubH° | 90.90 ± 0.40 | kJ/mol | NIST |
ΔvapH° | 91.80 | kJ/mol | NIST |
log10WS | -1.56 | Aq. Sol... | |
logPoct/wat | 1.393 | Crippen Calculated Property | |
McVol | 113.130 | ml/mol | McGowan Calculated Property |
Pc | 4260.71 | kPa | Joback Calculated Property |
Inp | 1490.00 | NIST | |
Tboil | 582.57 | K | Joback Calculated Property |
Tc | 787.82 | K | Joback Calculated Property |
Tfus | [370.00; 374.45] | K | |
Tfus | 373.65 | K | Aq. Sol... |
Tfus | 374.45 | K | KDB |
Tfus | 374.05 ± 0.50 | K | NIST |
Tfus | 370.00 ± 6.00 | K | NIST |
Tfus | 374.00 ± 3.00 | K | NIST |
Vc | 0.418 | m3/kmol | Joback Calculated Property |
Property | Value | Unit | Temperature (K) | Source |
---|---|---|---|---|
Cp,gas | [257.47; 305.30] | J/mol×K | [582.57; 787.82] | |
Cp,gas | 257.47 | J/mol×K | 582.57 | Joback Calculated Property |
Cp,gas | 266.70 | J/mol×K | 616.78 | Joback Calculated Property |
Cp,gas | 275.42 | J/mol×K | 650.99 | Joback Calculated Property |
Cp,gas | 283.63 | J/mol×K | 685.20 | Joback Calculated Property |
Cp,gas | 291.34 | J/mol×K | 719.41 | Joback Calculated Property |
Cp,gas | 298.56 | J/mol×K | 753.62 | Joback Calculated Property |
Cp,gas | 305.30 | J/mol×K | 787.82 | Joback Calculated Property |
η | [0.0000920; 0.0031310] | Pa×s | [351.84; 582.57] | |
η | 0.0031310 | Pa×s | 351.84 | Joback Calculated Property |
η | 0.0013019 | Pa×s | 390.30 | Joback Calculated Property |
η | 0.0006336 | Pa×s | 428.75 | Joback Calculated Property |
η | 0.0003472 | Pa×s | 467.20 | Joback Calculated Property |
η | 0.0002085 | Pa×s | 505.66 | Joback Calculated Property |
η | 0.0001345 | Pa×s | 544.12 | Joback Calculated Property |
η | 0.0000920 | Pa×s | 582.57 | Joback Calculated Property |
ΔfusH | 24.00 | kJ/mol | 374.60 | NIST |
ΔsubH | [90.80; 104.70] | kJ/mol | [319.34; 360.50] | |
ΔsubH | 104.70 ± 0.30 | kJ/mol | 319.34 | NIST |
ΔsubH | 101.20 | kJ/mol | 335.50 | NIST |
ΔsubH | 90.80 ± 0.40 | kJ/mol | 360.50 | NIST |
ΔsubH | 90.90 | kJ/mol | 360.50 | NIST |
Psub | [9.80e-04; 0.02] | kPa | [342.40; 371.50] | |
Psub | 9.80e-04 | kPa | 342.40 | Thermod... |
Psub | 1.52e-03 | kPa | 346.20 | Thermod... |
Psub | 1.81e-03 | kPa | 348.20 | Thermod... |
Psub | 2.21e-03 | kPa | 350.30 | Thermod... |
Psub | 2.72e-03 | kPa | 352.20 | Thermod... |
Psub | 3.47e-03 | kPa | 354.30 | Thermod... |
Psub | 4.19e-03 | kPa | 356.20 | Thermod... |
Psub | 5.36e-03 | kPa | 358.90 | Thermod... |
Psub | 6.80e-03 | kPa | 361.40 | Thermod... |
Psub | 8.13e-03 | kPa | 363.20 | Thermod... |
Psub | 0.01 | kPa | 366.20 | Thermod... |
Psub | 0.01 | kPa | 367.90 | Thermod... |
Psub | 0.02 | kPa | 371.50 | Thermod... |
Property | Value | Unit | Temperature (K) | Source |
---|---|---|---|---|
Pvap | [6.85e-05; 4.50e-04] | kPa | [319.15; 335.15] | KDB Vap... |
Equation | ln(Pvp) = A + B/T + C*ln(T) + D*T^2 | |||
Coefficient A | -1.20317e+02 | |||
Coefficient B | -6.18426e+03 | |||
Coefficient C | 2.28341e+01 | |||
Coefficient D | -1.51976e-05 | |||
Temperature range, min. | 319.15 | |||
Temperature range, max. | 335.15 | |||
Pvap | 6.85e-05 | kPa | 319.15 | Calculated Property |
Pvap | 8.51e-05 | kPa | 320.93 | Calculated Property |
Pvap | 1.05e-04 | kPa | 322.71 | Calculated Property |
Pvap | 1.30e-04 | kPa | 324.48 | Calculated Property |
Pvap | 1.61e-04 | kPa | 326.26 | Calculated Property |
Pvap | 1.99e-04 | kPa | 328.04 | Calculated Property |
Pvap | 2.44e-04 | kPa | 329.82 | Calculated Property |
Pvap | 3.00e-04 | kPa | 331.59 | Calculated Property |
Pvap | 3.68e-04 | kPa | 333.37 | Calculated Property |
Pvap | 4.50e-04 | kPa | 335.15 | Calculated Property |
Find more compounds similar to Benzoic acid, 2-methoxy-.
Note: Cheméo is only indexing the data, follow the source links to retrieve the latest data. The source is also providing more information like the publication year, authors and more. Take the time to validate and double check the source of the data.