Datasets
-
Activity coefficient (2)
-
Mole fraction (2)
-
Tboil - Boiling temperature at pressure P, K (2)
Activity coefficient of Cyclohexene (2)
[ref]
Fixed |
Measured |
Temperature, K - Liquid |
Pressure, kPa - Liquid |
Mole fraction of Cyclohexene (2) - Liquid |
Activity coefficient of Cyclohexene (2) - Liquid |
298.00 |
238.00 |
0.0000 |
7.4 |
Activity coefficient of Cyclohexene (2)
[ref]
Fixed |
Measured |
Temperature, K - Liquid |
Pressure, kPa - Liquid |
Mole fraction of Cyclohexene (2) - Liquid |
Activity coefficient of Cyclohexene (2) - Liquid |
298.00 |
238.00 |
0.0000 |
7.4 |
Mole fraction of Cyclohexene (2)
[ref]
Operational condition: Pressure, kPa =
100 (Liquid)
Mole fraction of Cyclohexene (2) - Liquid |
Mole fraction of Cyclohexene (2) - Gas |
0.0160 |
0.1540 |
0.0500 |
0.3850 |
0.1010 |
0.5880 |
0.1290 |
0.6490 |
0.1610 |
0.6990 |
0.2010 |
0.7340 |
0.2270 |
0.7480 |
0.2850 |
0.7800 |
0.3300 |
0.7970 |
0.3730 |
0.8070 |
0.4270 |
0.8150 |
0.4550 |
0.8200 |
0.5030 |
0.8280 |
0.5460 |
0.8350 |
0.5910 |
0.8490 |
0.6330 |
0.8470 |
0.6790 |
0.8570 |
0.7300 |
0.8610 |
0.7880 |
0.8680 |
0.8360 |
0.8760 |
0.8930 |
0.8930 |
0.9450 |
0.9240 |
0.9750 |
0.9560 |
Mole fraction of Cyclohexene (2)
[ref]
Operational condition: Pressure, kPa =
100 (Liquid)
Mole fraction of Cyclohexene (2) - Liquid |
Mole fraction of Cyclohexene (2) - Gas |
0.0160 |
0.1540 |
0.0500 |
0.3850 |
0.1010 |
0.5880 |
0.1290 |
0.6490 |
0.1610 |
0.6990 |
0.2010 |
0.7340 |
0.2270 |
0.7480 |
0.2850 |
0.7800 |
0.3300 |
0.7970 |
0.3730 |
0.8070 |
0.4270 |
0.8150 |
0.4550 |
0.8200 |
0.5030 |
0.8280 |
0.5460 |
0.8350 |
0.5910 |
0.8490 |
0.6330 |
0.8470 |
0.6790 |
0.8570 |
0.7300 |
0.8610 |
0.7880 |
0.8680 |
0.8360 |
0.8760 |
0.8930 |
0.8930 |
0.9450 |
0.9240 |
0.9750 |
0.9560 |
Boiling temperature at pressure P, K
[ref]
Operational condition: Pressure, kPa =
100 (Liquid)
Mole fraction of Cyclohexene (2) - Liquid |
Boiling temperature at pressure P, K - Liquid |
0.0160 |
392.57 |
0.0500 |
383.81 |
0.1010 |
373.63 |
0.1290 |
370.16 |
0.1610 |
366.56 |
0.2010 |
363.96 |
0.2270 |
362.46 |
0.2850 |
360.14 |
0.3300 |
358.78 |
0.3730 |
357.80 |
0.4270 |
356.89 |
0.4550 |
356.57 |
0.5030 |
356.03 |
0.5460 |
355.59 |
0.5910 |
355.24 |
0.6330 |
354.94 |
0.6790 |
354.66 |
0.7300 |
354.38 |
0.7880 |
354.19 |
0.8360 |
354.05 |
0.8930 |
353.99 |
0.9450 |
354.30 |
0.9750 |
354.86 |
Boiling temperature at pressure P, K
[ref]
Operational condition: Pressure, kPa =
100 (Liquid)
Mole fraction of Cyclohexene (2) - Liquid |
Boiling temperature at pressure P, K - Liquid |
0.0160 |
392.57 |
0.0500 |
383.81 |
0.1010 |
373.63 |
0.1290 |
370.16 |
0.1610 |
366.56 |
0.2010 |
363.96 |
0.2270 |
362.46 |
0.2850 |
360.14 |
0.3300 |
358.78 |
0.3730 |
357.80 |
0.4270 |
356.89 |
0.4550 |
356.57 |
0.5030 |
356.03 |
0.5460 |
355.59 |
0.5910 |
355.24 |
0.6330 |
354.94 |
0.6790 |
354.66 |
0.7300 |
354.38 |
0.7880 |
354.19 |
0.8360 |
354.05 |
0.8930 |
353.99 |
0.9450 |
354.30 |
0.9750 |
354.86 |
Sources